ULTRAMID® T KR 4365 G5 Black 00100 Polyamide is a glass fiber reinforced, flame retardant, partially aromatic polyamide for injection molding. It boasts good mechanical properties, low water absorption, high melting point (295°C), high tracking resistance, low tendency to form deposits on electrical contacts, very resistant to electrolytic corrosion, and resistant to soldering temperatures. Additionally, it can be electroplated.

Polymer Name: Polyamide 6/6T (PA 6/6T)

Processing Methods: Injection Molding

Fillers Included: Glass Fiber

  • TypeDocument Name
View All Documents

Enhanced TDS

Identification & Functionality

Chemical Family
Fillers Included
Polymer Name
Plastics & Elastomers Functions
Technologies
Product Families

Features & Benefits

Applications & Uses

Properties

Color (Properties)
Flame Rating
Physical Form
Mechanical Properties
ValueUnitsTest Method / Conditions
Tensile Modulus (Cond.)8000MPaISO 527-1/-2
Tensile Modulus (Dry)8300MPaISO 527-1/-2
Stress at Break (Cond.)140MPaISO 527-1/-2
Stress at Break (Dry)150MPaISO 527-1/-2
Strain at Break (Dry)3%ISO 527-1/-2
Tensile Creep Modulus (1000 H, Strain < 0.5%, at 23°C) (Cond.)6400MPaISO 899-1
Flexural Modulus (Dry)7500.0MPaISO 178
Flexural Strength (Dry)210.0MPaISO 178
Charpy Unnotched Impact Strength (at 23°C) (Dry) 70.0kJ/m²ISO 179/1eU
Charpy Unnotched Impact Strength (at 23°C) (Cond.) 55.0kJ/m² ISO 179/1eU
Charpy Notched Impact Strength (23°C) (Dry)8kJ/m² ISO 179/1eA
Izod Notched Impact Strength (Cond.) (at 23°C)8kJ/m²ISO 180/A
Charpy notched impact strength (23°C) (Cond.)7kJ/m² ISO 179/1eA
Izod Notched Impact Strength (Dry) (at 23°C)9kJ/m²ISO 180/A
Typical Properties
ValueUnitsTest Method / Conditions
Polymer Abbreviation (at 23°C)PA6T/6-GF25 FR(52)--
Density (at 23°C)1380kg/m³ISO 1183
Viscosity Number (0.5% in 96% H₂SO₄) (at 23°C)130cm³/gISO 307, 1157, 1628
Water Absorption (Equilibrium in Water, at 23°C)5 - 6%Similar to ISO 124
Moisture Absorption, Equilibrium (at 23°C/50% r.h)1.1 - 1.5%Similar to ISO 125
Bulk Density0.7g/cm³-
Thermal Properties
ValueUnitsTest Method / Conditions
Deflection Temp. Under Load 1.8 Mpa (Hdt A)220°CISO 75-1/-2
Service Temperature (Short Cycle Operation)max. 270°C-
Temperature Index at 50% Loss of Tensile Strength After 20000 H 125°CIEC 60216
Temperature Index (at 50% loss of tensile Strength after 5000 H)150°CIEC 60216
Coefficient of Linear Thermal Expansion, Longitudinal (at 23°C - 80°C)24.0×10⁻⁶/KISO 11359-1/-2
Coefficient of Linear Thermal Expansion, Transverse (at 23°C - 80°C)67.0×10⁻⁶/KISO 11359-1/-2
Thermal Conductivity0.31W/(m K)DIN 52612-1
Specific Heat Capacity1400J/(kg*K)-
Electrical Properties
ValueUnitsTest Method / Conditions
Relative Permittivity (1 Mhz) (Dry)4-IEC 62631-2-1
Dissipation Factor (1 Mhz) (Dry)200.0×10⁻⁴IEC 62631-2-1
Volume Resistivity (Cond.)1×10¹¹Ohm.mIEC 62631-3-1
Volume Resistivity (Dry)1×10¹²Ohm.mIEC 62631-3-1
Surface Resistivity (Cond.)1×10¹³OhmIEC 62631-3-2
Comparative Tracking Index - CTI (Cond.)600-IEC 60112,Test LIquid A
Electric Strength K20/K20, (60*60*1 mm³) (Cond.)33kV/mmIEC 60243-1
Electric Strength K20/K20, (60*60*1 mm³) (Dry)37kV/mmIEC 60243-1
Shrinkage
ValueUnitsTest Method / Conditions
Molding Shrinkage (Normal)1%ISO 294-4
Processing Shrinkage, Constrained, Longitudinal (Tm = 320°C, Tw = 100°C) ⁴0.4%-
Flammability
ValueUnitsTest Method / Conditions
Glow Wire Flammability Index - GWFI (at D < 0.75mm Thickness)960°CIEC 60695-2-12
Glow Wire Ignition Test - GWIT (at D = 0.75 mm Thickness)775°CIEC 60695-2-13
Oxygen Index26.0%ISO 4589-1/-2
Processing Parameters
ValueUnitsTest Method / Conditions
Melting Temperature 295.0°CISO 11357-1/-3 /DSC
Injection Molding
ValueUnitsTest Method / Conditions
Melt Temperature (Range)310 - 330°C
Mold Temperature (Range)80 - 120°C-
Residence Timemax. 5min
Drying
ValueUnitsTest Method / Conditions
Moisture Content (Recommended) ¹0.01 - 0.04%-
Dryer Temperature ²110°C-
Drying Time ³8h-
Machine Settings
ValueUnitsTest Method / Conditions
Temperature Hopper Throat80°C-
Cylinder Temperature 1 (Feed Zone)300°C-
Cylinder Temperature 2 (Compression)310°C-
Cylinder Temperature 3 (Metering - Zone, in Front of The Screw)320°C-
Cylinder Temperature 4 (Nozzle)320°C-
Peripheral Screw Speedmax. 0.3m/s
Processing Properties
ValueUnitsTest Method / Conditions
Melt Temperature (Injection Molding/Extrusion)310 - 330°C-
Mold Temperature (Injection Molding)80 - 120°C-
Molding shrinkage (Parallel) 0.55%ISO 294-4
Molding Shrinkage³ (Constrained) 0.4%
Molding Shrinkage (Normal)1%ISO 294-4
Note
  1. If product name or properties don't state otherwise.
  2. The asterisk symbol '*' signifies inapplicable properties.
  3. Test box with central gating, dimensions of base (107*47*1,5) mm, processing condition: TM = 320°C (unreinforced) or 330°C (reinforced), TW = 80°C
Note
  1.  If product name or properties don't state otherwise.
  2. The asterisk symbol '*' signifies inapplicable properties.
  3. Test box with central gating, dimensions of base (107*47*1,5) mm, processing condition: TM = 320°C (unreinforced) or 330°C (reinforced), TW = 80°C

Regulatory & Compliance

Safety & Health

Product Safety

y In case processing is done under conditions as recommended (cf. processing data sheet) melts are thermally stable and do not generate hazards by molecular degradation or the evolution of gases and vapors.

Like all thermoplastic polymers the product decomposes on exposure to excessive thermal load, e.g. when it is overheated or as a result of cleaning by burning off.

Product Safety

In case processing is done under conditions as recommended (cf. processing data sheet) melts are thermally stable and do not generate hazards by molecular degradation or the evolution of gases and vapors.

Like all thermoplastic polymers the product decomposes on exposure to excessive thermal load, e.g. when it is overheated or as a result of cleaning by burning off.

Safety Instructions

Provide suitable exhaust ventilation at the drying process and in the area surrounding the melt outlet of processing machines.

Closed containers should only be opened in well-ventilated areas. Ensure thorough ventilation of stores and work areas.

When incorrectly processing an unpleasant odour can be produced, especially when the recommended processing parameters are exceeded. Check

  • Moisture content of pellets
  • Melt temperature
  • Residence time

When there is a strong odour, immediately check processing parameters, ventilate the area well and recheck moisturecontent of material. If necessary stop processing and redry the material.
Any short stoppages in production, it is recommended that you inject material into the mould not purge an air shot. It is advisable to dispose of purgings etc into water containers.

Packaging & Availability

Packaging Information

Standard packs are bag and bulk container (octagonal IBC=intermediate bulk container made from corrugated board with a liner bag).

Other packaging materials and shipping in road or rail silo wagons are possible by agreement.

The containers should only be opened immediately before processing or drying.

Packaging Information

Standard packs are bag and bulk container (octagonal IBC=intermediate bulk container made from corrugated board with a liner bag).

Other packaging materials and shipping in road or rail silo wagons are possible by agreement.

Storage & Handling

Storage Information

The containers should only be opened immediately before processing or drying.

To ensure that the delivered product absorbs as little moisture as possible, the containers should be stored in dry rooms and always carefully closed again after partial quantities have been withdrawn. In principle, the product can be stored for a long period of time.

Containers stored in cold rooms should be equalized to ambient temperature before opening in order to avoid condensation on the granules.

Regardless of the storage conditions, the product should be pre-dried according to our recommendations and the machine should preferably be loaded using a closed conveyor system.

Storage Information

To ensure that the delivered product absorbs as little moisture as possible, the containers should be stored in dry rooms and always carefully closed again after partial quantities have been withdrawn.

In principle, the product can be stored for a long period of time.

Containers stored in cold rooms should be equalized to ambient temperature before opening in order to avoid condensation on the granules.

Regardless of the storage conditions, the product should be pre-dried according to our recommendations and the machine should preferably be loaded using a closed conveyor system.