ULTRAMID® B3WG10 Black 00564 Polyamide

1 of 141 products in this brand
ULTRAMID® B3WG10 Black 00564 Polyamide is a polyamide glass fiber reinforced injection molding grade. Ideal for industrial parts needing high rigidity and heat aging resistance.

Polymer Name: Polyamide 6 (PA 6)

Processing Methods: Injection Molding

Fillers Included: Glass Fiber

Flexural Modulus:: 9,000.0 MPa

  • TypeDocument Name
View All Documents

Enhanced TDS

Identification & Functionality

Chemical Family
Fillers Included
Polymer Name
Plastics & Elastomers Functions
Technologies
Product Families

Features & Benefits

Applications & Uses

Markets
Applications
Plastics & Elastomers End Uses
Plastics & Elastomers Processing Methods

Properties

Color (Properties)
Mechanical Properties
ValueUnitsTest Method / Conditions
Tensile Modulus (Cond.)11000MPaISO 527-1/-2
Tensile Modulus (Dry)16000MPaISO 527-1/-2
Stress at Break (Cond.)160MPaISO 527-1/-2
Stress at Break (Dry)235MPaISO 527-1/-2
Strain at Break (Dry)3%ISO 527-1/-2
Strain at Break (Cond.)5.5%ISO 527-1/-2
Tensile Creep Modulus (1000 H, Strain < 0.5%, at 23°C)7400MPaISO 899-1
Flexural Modulus (Dry)15000.0MPaISO 178
Flexural Modulus (Cond.)9000MPaISO 178
Flexural Strength (Cond.)240MPaISO 178
Flexural Strength (Dry)320.0MPaISO 178
Charpy Unnotched Impact Strength (23°C) (Cond.) 110kJ/m² ISO 179/1eU
Charpy Unnotched Impact Strength (23°C) (Dry) 100 kJ/m² ISO 179/1eU
Charpy Unnotched Impact Strength (at -30°C) (Dry) 90.0 kJ/m² ISO 179/1eU
Charpy Unnotched Impact Strength (at -30°C)(Cond.) 98.0kJ/m² ISO 179/1eU
Charpy Notched Impact Strength (23°C) (Cond.)22kJ/m² ISO 179/1eA
Charpy Notched Impact Strength (23°C) (Cond.)30kJ/m² ISO 179/1eA
Charpy Notched Impact Strength (Dry) (at -30°C)16kJ/m²ISO 179/1eA
Charpy Notched Impact Strength (-30°C) (Dry) 16kJ/m² ISO 179/1eA
Izod Notched Impact Strength (Dry) (at 23°C) 190.0J/mASTM D 256
Izod Notched Impact Strength (Cond.) (at 23°C) 340.0J/mASTM D 256
Tensile Modulus (HDT A) (Dry) (at 80°C)8500MPaISO 527-1/-2
Izod Notched Impact Strength (23 °C) (Dry)190J/m ASTM D 256
Stress at Break (HDT B) (Dry) (at 80°C)130MPaISO 527-1/-2
Strain at Break (Short Cycle Operation) (Dry) (at 80°C)6%ISO 527-1/-2
Deflection Temperature Under Load 0.45 MPa (HDT B) 220°C ISO 75-1/-2
Charpy unnotched impact strength (23°C) (Dry)100kJ/m² ISO 179/1eU
Typical Properties
ValueUnitsTest Method / Conditions
Polymer Abbreviation (at 23°C)PA6-GF50--
Density (at 23°C)1550kg/m³ISO 1183
Viscosity Number (0.5% in 96% H₂SO₄) (at 23°C)135cm³/gISO 307, 1157, 1628
Water Absorption (Equilibrium in Water, at 23°C)4.5 - 5.1%Similar to ISO 90
Moisture Absorption, Equilibrium (at 23°C/50% r.h)1.3 - 1.7%Similar to ISO 91
Melt Volume Rate (275°C/5 Kg at 23°C) 22.0cm³/10min
Bulk Density0.7g/cm³-
Thermal Properties
ValueUnitsTest Method / Conditions
Melting Temperature 220.0 °C ISO 11357-1/-3/DSC
Deflection Temperature Under Load 1.8 Mpa (HDT A) 215.0°CISO 75-1/-2
Service Temperature (Short Cycle Operation)max. 200°C-
Temperature Index at 50% Loss of Tensile Strength after 5000 H175°CIEC 60216
Temperature Index (at 50% loss of tensile Strength after 20000 H)145°CIEC 60216
Coefficient of Linear Thermal Expansion, Longitudinal (at 23°C - 55°C)15.0×10⁶/KISO 11359-1/-2
Coefficient of Linear Thermal Expansion, Transverse (at 23°C - 55°C)73.0×10⁻⁶/KISO 11359-1/-2
Thermal Conductivity0.38W/(m K)DIN 52612-1
Specific Heat Capacity1300J/(kg*K)-
Electrical Properties
ValueUnitsTest Method / Conditions
Relative Permittivity (1 Mhz) (Dry)4.2-IEC 62631-2-1
Relative Permittivity (1 Mhz) (Cond.)6.1-IEC 62631-2-1
Dissipation Factor (1 Mhz) (Dry)140.0×10⁻⁴IEC 62631-2-1
Dissipation Factor (1 MHz) (Cond.)1400.0×10⁻⁴IEC 62631-2-1
Volume Resistivity (Cond.)1×10⁹Ohm.mIEC 62631-3-1
Volume Resistivity (Dry)1×10¹²Ohm.mIEC 62631-3-1
Surface Resistivity (Cond.)1×10⁹OhmIEC 62631-3-2
Surface Resistivity (Dry)1×10¹²OhmIEC 62631-3-2
Electric Strength K20/K20, (60*60*1 mm³) (Cond.)31kV/mmIEC 60243-1
Electric Strength K20/K20, (60*60*1 mm³) (Dry)40kV/mmIEC 60243-1
Shrinkage
ValueUnitsTest Method / Conditions
Molding Shrinkage (Normal)0.7%ISO 294-4
Processing Shrinkage, Constrained, Longitudinal (Tm = 300°C, Tw = 80°C) ⁴0.3%-
Flammability
ValueUnitsTest Method / Conditions
Ul94 Flammability Rating (at Nominal 1.5mm)HB (1.55)class (mm)IEC 60695-11-10
Ul94 Flammability RatingHB (0.83)class (mm)IEC 60695-11-10
Yellow Card availableYes--
Automotive Materials (Thickness > 1mm) ⁴Passed-ISO 3795, FMVSS 302
Total Amino Acid Profile
ValueUnitsTest Method / Conditions
Izod Notched Impact Strength (23 °C) (Cond.)340J/mASTM D 256
Injection Molding
ValueUnitsTest Method / Conditions
Melt Temperature (Range)280 - 300°C
Mold Temperature (Range)80 - 90°C-
Residence Timemax. 10min-
Drying
ValueUnitsTest Method / Conditions
Moisture Content (Recommended) ¹0.03 - 0.06%-
Dryer Temperature ²80°C-
Drying Time ³4h-
Moisture Contentmax. 0.20%-
Machine Settings
ValueUnitsTest Method / Conditions
Temperature Hopper Throat80°C-
Cylinder Temperature 1 (Feed Zone)270°C-
Cylinder Temperature 2 (Compression)280°C-
Cylinder Temperature 3 (Metering - Zone, in Front of The Screw)290°C-
Cylinder Temperature 4 (Nozzle)290°C-
Peripheral Screw Speedmax. 0.11m/s-
Processing Properties
ValueUnitsTest Method / Conditions
Melt Volume-Flow Rate - (275°C/5 Kg) 22.0 cm³/10minISO 1133
Melt Temperature (Injection Molding/Extrusion)280 - 300°C-
Mold Temperature (Injection Molding)80 - 90°C-
Molding Shrinkage (Constrained) ³0.3%
Molding Shrinkage (Parallel)0.2%ISO 294-4
Pre/Post - Processing, Pre - Drying, Temperature80°C-
Pre/Post - Processing, Pre - Drying, Time4h-
Melt Temperature280°C-
Mold Temperature80°C-
Flowability (Flow Length, Spiral D = 2.0 mm)41cmBASF Method
Note
  1. If product name or properties don't state otherwise.
  2. The asterisk symbol '*' signifies inapplicable properties.
  3. Test box with central gating, dimensions of base (107*47*1,5) mm, processing condition: TM = 280°C, TW = 80°C

Regulatory & Compliance

Safety & Health

Product Safety

In case processing is done under conditions as recommended (cf. processing data sheet) melts are thermally stable and do not generate hazards by molecular degradation or the evolution of gases and vapors.

Like all thermoplastic polymers the product decomposes on exposure to excessive thermal load, e.g. when it is overheated or as a result of cleaning by burning off.

Storage & Handling

Storage Information

The containers should only be opened immediately before processing or drying.

To ensure that the delivered product absorbs as little moisture as possible, the containers should be stored in dry rooms and always carefully closed again after partial quantities have been withdrawn.

In principle, the product can be stored for a long period of time.

Containers stored in cold rooms should be equalized to ambient temperature before opening in order to avoid condensation on the granules.

Regardless of the storage conditions, the product should be pre-dried according to our recommendations and the machine should preferably be loaded using a closed conveyor system.