Properties
- Color (Properties)
- Flame Rating
- Mechanical Properties
Value Units Test Method / Conditions Tensile Modulus 9700 MPa ISO 527-1/-2 Stress at Break 140.0 MPa ISO 527-1/-2 Strain at Break 2.7 % ISO 527-1/-2 Charpy Unnotched Impact Strength (at 23°C) 60 kJ/m² ISO 179/1eU Charpy Unnotched Impact Strength (at -30°C) 50 kJ/m² ISO 179/1eU Charpy Notched Impact Strength (at 23°C) 7.5 kJ/m² ISO 179/1eA Flexural Modulus 10000.0 MPa ISO 178 Flexural Strength 210.0 MPa ISO 178 Izod notched Impact Strength (23°C) 7.8 kJ/m² ISO 180/A - Typical Properties
Value Units Test Method / Conditions Polymer Abbreviation PBT-GF30 - - Density 1530 kg/m³ ISO 1183 Viscosity Number (Solution 0,005 g/ml Phenole/1,2 Dichlorbenzol 1:1) 90 cm³/g ISO 307, 1157, 1628 Natural (at 23°C) Passed - - Black (at 23°C) Passed - - Water Absorption (Equilibrium in Water, at 23°C) 0.4 % similar to ISO 62 Moisture Absorption, Equilibrium (at 23°C/50% r.h) 0.2 % similar to ISO 62 Bulk Density 0.7 - 0.8 g/cm³ - - Thermal Properties
Value Units Test Method / Conditions Melting Temperature 223.0 °C ISO 11357-1/-3,DSC HDT A (1.80 MPa) 205 °C ISO 75-1/-2 HDT B (0.45 MPa) 220 °C ISO 75-1/-2 Service Temperature (Short Cycle Operation) max. 210 °C - Temperature Index (at 50% loss of tensile Strength after 20000 H) 150 °C IEC 60216 Temperature Index (at 50% loss of tensile Strength after 5000 H) 170 °C IEC 60216 Coefficient of Linear Thermal Expansion, Longitudinal (at 23°C - 55°C) 25.0 x 10⁻⁶ /K ISO 11359-1/-2 Coefficient of Linear Thermal Expansion, Transverse (at 23°C - 55°C) 110.0 x 10⁻⁶ /K ISO 11359-1/-2 - Electrical Properties
Value Units Test Method / Conditions Relative Permittivity (100 Hz) 4 - IEC 62631-2-1 Relative Permittivity (1 MHz) 3.8 - - Dissipation Factor (100 Hz) 25.0 x 10⁻⁴ IEC 62631-2-1 Dissipation Factor (1 MHz) 170.0 x 10⁻⁴ IEC 62631-2-1 Volume Resistivity 1×10 ¹⁴ Ohm.m IEC 62631-3-1 Surface Resistivity 1×10¹³ Ohm IEC 62631-3-2 Comparative Tracking Index - CTI 350 - IEC 60112,Test LIquid A Electric Strength K20/K20, (60*60*1 mm³) 37 kV/mm IEC 60243-1 - Shrinkage
Value Units Test Method / Conditions Molding Shrinkage (Parallel) 0.4 % ISO 294-4 Molding Shrinkage (Normal) 1.1 % ISO 294-4 Molding Shrinkage (Free, transversal, Plate, with Film Gate) ⁵ 1.1 % Molding Shrinkage (Free, Longitudinal, Plate, with Film Gate) ⁵ 0.27 % - Flammability
Value Units Test Method / Conditions Burning Behaviour (at Thickness D = 1.5 mm) HB class IEC 60695-11-12 Automotive Materials (Thickness D > 1mm) ³ Passed - ISO 3795, FMVSS 302 - Injection Molding
Value Units Test Method / Conditions Melt Temperature (Range) 230 - 275 °C Mold Temperature (Range) 60 - 100 °C - - Drying
Value Units Test Method / Conditions Moisture Content max. 0.04 % - Dryer Temperature ⁴ 80 - 120 °C Dryer Temperature Optimal ⁴ 100.0 °C Drying Time 4 h - - Machine Settings
Value Units Test Method / Conditions Temperature Hopper Throat 80 °C - Cylinder Temperature 1 (Feed Zone) 250 °C - Cylinder Temperature 2 (Compression) 255 °C - Cylinder Temperature 3 (Metering - Zone, in Front of The Screw) 260 °C - Cylinder Temperature 4 (Nozzle) 260 °C - Peripheral Screw Speed max. 0.25 m/s - - Processing Properties
Value Units Test Method / Conditions Melt Volume Flow Rate (at 250°C and 10 kg) 23.0 cm³/10min ISO 1133 Mould Temperature (Injection Moulding) 60 - 100 °C - - Note
1. If product name or properties don't state otherwise.
2. The asterisk symbol '*' signifies inapplicable properties.
3. + = passed
4. Dry air dryer or vacuum dryer
5. Plate 150 x 150 x 3 mm, film gated
Regulatory & Compliance
- Certifications & Compliance
- Quality Standards
Safety & Health
- Product Safety
Ultradur® melts are stable at temperatures up to 280°C and do not give rise to hazards due to molecular degradation or the evolution of gases and vapors.
Like all thermoplastic polymers, however, Ultradur decomposes on exposure to excessive thermal stresses, e.g. when it is overheated or as a result of cleaning by burning off. At temperatures of > 290°C can be emitted: carbon monoxide, tetrahydrofuran.Under special fire conditions traces of other toxic substances are possible.
Formation of further decomposition and oxidation products depends upon the fire conditions. When Ultradur® is properly processed and there is adequate suction at the die no risks to health are to be expected.Further safety information see safety data sheet of individual product.
Packaging & Availability
- Packaging Conditions
Standard packaging includes the 25-kg-bag, the 1000 kg octabin (octagonal container) or the 1000 kg big bag.
All containers are tightly sealed and should be opened only immediately prior to processing.
Storage & Handling
- Storage Conditions
Ultradur® can be stored for a longer period of time in dry, well vented rooms without causingproblems in processing.
Ultradur® should generally have a moisture content of less than 0,04% when being processed.
In order to ensure reliable production, therefore, pre-drying should generally be the rule and the machine should be loaded via a closed conveyor system.
In order to prevent the formation of condensed water, containers stored in unheated rooms must only be opened when they have attained the temperature prevailing in the processing area.
Measurements have shown that the interior of a 25-kg bag originally at 5°C had reached the temperature of 20°C in the processing area only after 48 hours.